/ 中存储网

AIX5300小机报错 COMMUNICATION PROTOCOL ERROR解决方法

2015-06-02 13:03:45 来源:中存储

AIX5300小机报错 COMMUNICATION PROTOCOL ERROR解决方法

日志查看errpt报错信息如下:

LABEL: ISCSI_ERR10
IDENTIFIER: 1364248E

Date/Time: Sat Mar 2 19:36:14 BEIST 2013
Sequence Number: 247343
Machine Id: 00C97D104C00
Node Id: DBSERVER_A
Class: H
Type: TEMP
Resource Name: iscsi2
Resource Class: driver
Resource Type: qliscsi
Location: U7879.001.DQD404W-P1-C4-T1

Description
COMMUNICATION PROTOCOL ERROR

Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES


LABEL: ISCSI_ERR10
IDENTIFIER: 1364248E

Date/Time: Sat Mar 2 19:36:14 BEIST 2013
Sequence Number: 247342
Machine Id: 00C97D104C00
Node Id: DBSERVER_A
Class: H
Type: TEMP
Resource Name: iscsi2
Resource Class: driver
Resource Type: qliscsi
Location: U7879.001.DQD404W-P1-C4-T1

Description
COMMUNICATION PROTOCOL ERROR

Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES

Detail Data
SENSE DATA
0000 0000 0000 0083 0000 0005 0301 0000 0000 0000 0000 0000 0000 0000 0000 0000
0A01 026E 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

解决思路:

首先不能凭借 日志就完全肯定 就是HBA卡报错,一步步排错如下:


1,先执行 lsdev -Cc adapter
2,lsslot -c slot
通过这两个命令看下是否激活状态 如果有LPAR 在本机已分配就是激活 未分配 就不是激活的
3,看看存储和本地的多路径 lspath 查看下
日志有具体槽位的报错 ,看着是链路错误 不是卡的错误 具体查看一下HMC日志
通过以上几种方法基本可以定位
4 经常报磁盘错误 有可能是多路径的错误 并不是HBA 查看Hba卡的状态就知道了